Bentley Raceway and Cable Management CONNECT Edition Help

BRCM Configuration Variables

The following table lists the Bentley Raceway and Cable Management application specific variables that are used to configure the software and explain their purpose. Application variables are prefixed with "BRCM_" to set them apart from the standard MicroStation variables. Each configuration variable expects a valid value. An invalid value will not override a setting. You do not need to close and restart in order for the configuration variable change to take effect, unless noted

Name Operator Value Type Value (Typical) Description
BRCM_APPLICATION = String BRCM Short name of the application
BRCM_DB_CONNECTSTRING = String DSN=BRCMUSER;UID=BRCMUser;PWD=BRCM Connection String for SQL Server Database
BRCM_DB_ID = String MYWORKSET Prefix given to the SQL table names which typically matches the WorkSet name.
BRCM_DB_STATIONID = String $(computername) Unique work station ID.
BRCM_DIR C:\Program Files\Bentley\Bentley Raceway and Cable Management CONNECT Edition\BRCM\ Directory path
BRCM_FILE_UPDATE_OPTION 1 Controls how data is saved to the database when the design file is closed (0: no update, 1: Prompt to update, 2: silent update)
BRCM_IMODEL_PUBLISH_MODE 0 Not used in CONNECT Edition
BRCM_WS_EQUIPMENT = String C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\equipment Location of equipment data files
BRCM_WS_LANGUAGE = String EN Language Code for localized metadata files
BRCM_WS_METADATA = String C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\metadata Location of metadata files.
BRCM_WS_RACEWAY = String C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\raceway Location of raceway data files.
BRCM_WS_RACEWAY_TEMPLATES = String C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\raceway\Templates Location of raceway templates.
BRCM_WS_SCHEMAS = String C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\schemas Location of EC schema files.
BRCM_PW_SUBFOLDER_CPC = String \Cable Pull Cards Project subfolder for cable pull cards
BRCM_PW_SUBFOLDER_REPORTS = String \Reports Project subfolder for reports
BRCM_IMAGE_PATH = String C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Worksets\BRCM_EU_EN\Standards\BRCM\Reports\Images Location of the cable routing path images.
BRCM_OPM_CABLE_CONNECTION = String ELECTRICAL_DEVICE_OFFSET X,Y,Z Offset from the insertion point of the OPM equipment for electrical device.
BRCM_USER_DEFINED_CONFIGS = String $(APPDATA)/Bentley/$(BRCM_APPLICATION)/userconfigs/ As a BRCM administrator, you can now define custom ID, Raceway, and Duct Bank spacer configurations and adjust a configuration variable to control where these configurations are saved making it more convenient for you to control who has rights to modify them. The variable, BRCM_USER_DEFINED_CONFIGS by default is set to the local user's app data folder, but can be changed as you desire.